Solar Energy

Location
MONTHS (KCal/m2 - Day)
1
2
3
4
5
6
7
8
9
10
11
12
ADANA
1257
1970
2850
3616
4462
4658
4326
4238
3566
2634
1625
1258
ANTALYA
1554
1977
2868
3915
4386
4928
4994
4748
3740
2712
1907
1227
G. ANTEP
1479
2202
3023
4222
4378
5414
5280
5036
4013
2795
1894
1368
* This chart has been prepared in accordance with heat engineering and 1974 dated bulletin of the General Directorate of Meteorology. Values represent the energy occurred on horizontal surface.

Sukal Solar Energy Calculations


Daily Water Requirement

Daily hot water consumption has been regarded as 50 liters/day.

V = (No. of Consumer) x 50 liters/day. (It has been supposed that 4 people live in each house.)


Water’s Temperature of for Solar Collector Inlet

Temperature of the cold water going into the installation should be supposed 2-300C lower than the fresh air outdoor.


Temperature of Potable Water

Potable water is supposed 40-600for usage purposes. Daily heat requirement for providing hot water (Q) is:

No. of collectors after required daily energy amount (Q) is found:

Example: Let’s find out how many collectors are necessary in order to meet
a 10-family flat’s hot water requirement: (Let’s make the calculations according to September.)

Daily hot water requirement; V = 10 x 4 x 50 V = 2000 liters/day

Required energy; Q = 60.000 KCal/day


SUKAL Solar Collector Sizes


150 liter capacity hot water tank,
500 liters cold water tank having base made of profile, optimum and easy mounting.